hit counter script

Interconnection Diagram; External Signals And Connections; Battery Connector; Fig 2 Ipower Distribution Diagram - Nokia RH-53 Manual

System module
Table of Contents

Advertisement

RH-53/54
8-System Module

Interconnection Diagram

Battery

External Signals and Connections

Battery connector

As a difference to previous NMP Battery Interfaces, BTEMP has been removed and battery
temperature is estimated by measurement in Transceiver PWB with a separate NTC resistor.
Thus the Battery Interface has only 3 contacts. BSI ranges has been altered and Battery Inter-
face will not support NiMh batteries.
Name
VBAT
GND
BSI
ISSUE 1 09/2004
Figure 2:IPower distribution diagram
Baseband
UEM
RF Regulators
Baseband
LED+
Regulators
RTC
LED
Driver
VBAT
Boomer
PA Supply
System Connector
Table 6: Battey connetor
Description
Battery voltage terminal.
Battery ground terminal.
Battery size identification.
COMPANY CONFIDENTIAL
Copyright © 2004 Nokia. All Rights Reserved.
VR1A
VR2-7
6
VSIM
VCORE
VANA
VIO
VFLASH1
CHACON
Battery calibration.
Flash and local mode forcing.
Nokia Customer Care
SIM
UPP
FLASH
LCD
Test usage
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rh-54