hit counter script

Reference File; Reference File Operation - Sony HDC4300 Service Manual

Hide thumbs Also See for HDC4300:
Table of Contents

Advertisement

7-5.

Reference File

Reference files can be stored in the camera and USB drive.
Reference files can also be stored in the memory stick if the master setup unit (MSU) is used. For details, refer to the
MSU operation manual.
Data is stored and called using the setup menu or MSU.
Reference files can be copied between cameras using the USB drive.
Note
Reference File stores the differential data taking the factory-setting as 0. Therefore, initializing the Reference File brings
the settings to the same status at the factory setting. If Lens File or OHB File retains the data, they need to be initialized
as well.
To initialize data, use the setup menu. You can select all file items or only specified items to initialize.
7-5-1.

Reference File Operation

Outline Figure of Operation
Camera unit
Current paint data
Output to hardware
Storing
Reference: Refer to step 1 of "Outline Figure of Operation".
Using FILE Menu of This Unit
Reference file is stored in the camera and the numerical data is displayed as 0. (Excluding some items. Refer to
File
Items".)
[FILE] → [REFERENCE] → [STORE FILE]
With MSU (Master Setup Unit)
1.
Press the FILE button in the functional operation area on the operation panel.
2.
Select [Reference] → [Reference Store] by the menu operation.
Reference file is stored in the camera and the numerical data is displayed as 0. (Excluding some items. Refer to
"7-8. File
Items".)
HDC4300
USB drive
Storing in
Reading from
USB drive
(Step 4)
Storing
(Step 1)
Reference File
Calling
(Step 2)
USB drive
(Step 3)
Initializing
Reference File
(Step 5)
factory-set value
(Initial value 0)
"7-8.
7-7

Advertisement

Table of Contents
loading

Table of Contents

Save PDF