1.3.1.2
Setting up SCALANCE M826 and network
Note
Familiarize yourself with the security instructions before you commission the device. You will
find the security instructions in the operating instructions.
Requirement
● All network nodes are in the same IP subnet.
Procedure
1. First unpack the M826 and check that it is undamaged.
2. Fit the power supply.
3. Wire X1 with X2, see Setup (Page 46).
4. Connect the devices to the local network via the Ethernet ports.
5. Turn the devices on. After connecting up, the fault LED (F) is lit red
6. Now, turn on the PC.
Result
The SCALANCE M826 devices are immediately operational without configuration. It may
take some time before the devices have negotiated the connection parameters.
You cannot access the WBM since this requires an IP address. The IP address can be
assigned by a DHCP server or with the Primary Setup Tool, see "Configuring SCALANCE
M826 with PST (Page 52)".
SCALANCE M-800 Getting Started
Getting Started, 06/2015, C79000-G8976-C337-04
WARNING
Use safety extra-low voltage only
The SCALANCE M826 is designed for operation with safety extra-low voltage. This
means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/
VDE0805 can be connected to the power supply terminals.
The power supply unit for the SCALANCE M826 power supply must meet NEC Class 2,
according to the National Electrical Code(r) (ANSI / NFPA 70).
Connecting SCALANCE M-800 to WAN
1.3 Connecting M826 with SHDSL
49