Creating A Vpn Connection - Siemens SCALANCE M-800 Series Getting Started

Simatic net industrial remote communication
Hide thumbs Also See for SCALANCE M-800 Series:
Table of Contents

Advertisement

NETMAP with SCALANCE M-800
6.2 NETMAP for the remote network
Requirement
● The SCALANCE M-800 is connected to the WAN , refer to "Connecting SCALANCE M-
800 to the WAN (Page 11)".
● The SCALANCE M-800 can be reached via the Admin PC and you are logged in to the
WBM as "admin".
Steps in configuration
The following steps are necessary
1. Creating a VPN connection (Page 212)
2. Creating NETMAP rules (Page 214)
6.2.1

Creating a VPN connection

Procedure
1. Click on "Security" > "IPSec VPN" in the navigation area and on the "General" tab in the
content area.
2. Select "Activate IPSec VPN" and click "Set Values".
3. Click on the "Remote End" tab in the content area and create the VPN partner with the
following settings:
4. Click on the "Connections" tab in the content area and create the VPN connection with
the following settings:
212
On the M816
Remote End Name
M816
Remote Mode
Standard
Remote Typ
manual
Remote Address
Reachable via a dynamic DNS
service, e.g. example.no-ip.com
Remote Subnet
192.168.20.0/24
On the M816
Connection Name
M816_to_M876_2
Operation
disable
Keyping Protocol
IKv2
Remote End Name
M816
Local Subnet
192.168.10.0/24
On the M876
M876
Standard
manual
Fixed IP address (WAN IP address) of
the M816, e.g. 91.19.6.84
192.168.10.0/24
On the M876
M876_to_M816_2
disable
IKv2
M876
192.168.20.0/24
SCALANCE M-800 Getting Started
Getting Started, 06/2015, C79000-G8976-C337-04