VPN tunnel between SCALANCE M87x and SINEMA RC Server
5.4 Configuring a remote connection on the M87x
5.4
Configuring a remote connection on the M87x
5.4.1
Secure VPN connection with fingerprint
Requirement
● On PC1/2 there are two Web browser windows open.
● Web browser 1:
You are logged in as the "admin" user to the WBM of the M874.
● Web browser 2:
You are logged on to the WBM of the SINEMA RC Server as user "service" or "admin".
● A valid KEY-PLUG is inserted in the M87x.
Procedure
1. Change to Web browser 1.
– In the address box of the Web browser, enter the LAN IP address of the M874, see
– Log in as the "admin" user and with the corresponding password.
– Click "System" > "SINEMA RC" in the navigation area.
– For "Sinema RC Address", enter the WAN IP address of the SINEMA RC Server, see
2. Change to Web browser 2.
– In the address box of the Web browser, enter the WAN IP address of the SINEMA RC
– Log in as the "admin" user and the corresponding password.
– In the navigation area, click "Remote connections" > "Devices".
– Click on the symbol
– Holding down the left mouse button, select the entry for device ID.
– Right-click on the selection and in the shortcut menu, select the copy command.
194
table "Settings used (Page 181)".
table "Settings used (Page 181)".
Server, see table "Settings used (Page 181)".
in "Actions" to open the device information.
Getting Started, 06/2015, C79000-G8976-C337-04
SCALANCE M-800 Getting Started