The parameters have the following meaning:
Parameter
l1
l2
poe
If you do not select any parameters from the parameter list, the default value "L1 and L2" is
used.
Result
The setting for monitoring the power supplies is configured.
Further notes
You can display the current setting with the show events faults config command.
You enable the function with the power command.
12.1.6.10

power pnio redundancy

Description
With the following devices, you can also configure which power supply will be monitored by
PROFINET:
● SCALANCE W788-x (RJ-45 variants)
● SCALANCE W748-1 RJ-45
● SCALANCE W774-1 (RJ-45 and M12 variant)
● SCALANCE W734-1 RJ-45
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
power pnio redundancy {all | l1-l2 | l1-poe | l2-poe}
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
No monitoring of power supply 1
No monitoring of power supply 2
No monitoring of the PoE power supply.
Diagnostics
12.1 Diagnostics
599