Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp notify <NotifyName> tag <TagName> type {Trap|Inform}
The parameters have the following meaning:
Parameter
NotifyName
tag
TagName
Type
Storage type
Result
The details of the SNMP notifications are configured.
Further notes
You delete the details of an SNMP notification with the no snmp notify command.
You display the configured SNMP notifications with the show snmp notif command.
You display the configured SNMP target addresses with the show snmp targetaddr
command.
8.6.2.15

no snmp notify

Description
With this command, you delete the details of the SNMP notifications.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
[{volatile|nonvolatile}]
Description
Name of the SNMP notification
Keyword for a target key
Name of the target key
Type of the SNMP notification
Specifies whether the settings remain
following a restart.
Network protocols
8.6 SNMP
Range of values / note
max. 32 characters
-
max. 32 characters
● Trap
Generates a trap.
● Inform
Generates a log entry or sends
an entry to the log server.
● :
The settings are lost after a
restart
● :
The settings are retained after
a restart
425