● The interface is an IP interface.
● You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
no ipv6 dhcp client request {dns-server-address | domain-name | sntp-
server-address | option <code (1-100)>}
The parameters have the following meaning:
Parameter
dns-server-
address
domain-name
sntp-server-
address
option
code
Result
The required configuration parameter is removed.
Further notes
You configure the request with the ipv6 dhcp client request command.
8.5

DHCP server

You can operate the device as a DHCP server. This allows IP addresses to be assigned
automatically to the connected devices. The IP addresses are either distributed dynamically
from an address band (pool) you have specified or a specific IP address is assigned to a
particular device.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
IPv6 address of the DNS server
Domain name
IPv6 address of the SNTP server
Keyword for the option code
ID of the DHCPV6 option
Network protocols
8.5 DHCP server
Range of values / note
-
-
-
-
Specify the required ID of the
DHCPv6 option.
1 ... 100