hit counter script

No Pool-Enable - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Network protocols
7.3 DHCP server
7.3.3.8

no pool-enable

Note
The command is only available with the following device:
• SCALANCE W722-1 RJ-45 (MLFB 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-0AB0
(US version))
• SCALANCE W761-1 RJ45 in access point mode (article number): 6GK5761-1FC00-0AA0
and 6GK5761-1FC00-0AB0 (US version))
Description
With this command you specify that this IPv4 address band will not be used.
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
cli(config-dhcp-pool-<ID>)#
Syntax
Call the command without parameter assignment:
no pool-enable
Result
The setting is disabled.
Further notes
You display the setting with the
You enable the setting with the
320
show ip dhcp-server pools
command.
pool-enable
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
command.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720Scalance w760

Table of Contents

Save PDF