6.3.3.8

no spanning-tree l2t-edge

Description
With this command, you disable the setting that an end device may be located at a layer 2
tunnel port.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree l2t-edge
Result
The setting is disabled.
Further notes
The automatic discovery of a bridge on the interface is disabled with the
edge
You can display the status of this function with the
6.3.3.9

spanning-tree mst configuration

Description
With this command, you change to the MSTP configuration mode.
Requirement
● MSTP is enabled
● Compatibility mode: MSTP
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
command.
spanning-tree l2t-
show spanning-tree l2t-edge
Network structures
6.3 Spanning Tree
command.