System time
5.1 System time setting
The parameters have the following meaning:
Parameter
name
begin
week
last
weekday
month
hour
end
Result
The entry for the start and end of daylight saving time was created.
5.1.2.5

no time dst

Description
With this command you delete the entry for the start and end of daylight saving time with the
specified name. If you do not specify a name as the parameter, all entries are deleted.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no time dst [<name(16>]
The parameter has the following meaning:
Parameter
name
Result
An entry or the entries for the start and end of daylight saving time was/were deleted.
118
Description
Name of the entry
Keyword for the start of daylight saving
time.
Calendar week in a month
Keyword for the last calendar week in a
month
Weekday
Month
Hour
Keyword for the end of daylight saving
time.
Description
Name of the entry
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Range of values / note
maximum 16 characters
-
1 ... 5
-
monday, tuesday, wednesday,
thursday, friday, saturday, sunday
january, february, march, april,
may, june, july, august, septem-
ber, october, november, decem-
ber
0 ... 23
-
Range of values / note
maximum 16 characters