5.1.2.1

time

Description
With this command, you configure the way in which the system time is obtained.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
time{manual|ntp|sntp|SINEC}
The parameters have the following meaning:
Parameter
manual
ntp
sntp
SINEC
Result
The method of obtaining the system time is configured.
Further notes
You display the settings for the system clock with the
5.1.2.2

time set

Description
With this command, you set the system clock.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
The system time is entered by the user
The system time is obtained from an NTP server
The system time is obtained from an SNTP server
The system time is obtained using the "SIMATIC time protocol"
5.1 System time setting
command.
show time
System time