Functions specific to SCALANCE
4.2 Signal recorder
Further notes
You stop the recording early with the
You display the status of the signal recorder and the recording with the
recorder <wlan 0/X>
4.2.5
wlan signal-recorder display sample_number (Client)
Description
With this command, you configure and start recording with the signal recorder. The
measured values are output in the CLI and logged in files. On completion of the recording,
the files can be downloaded as a zip file using http or tftp. The values are stored every 10
minutes. The file contains all values since the start of the recording.
Note
This command is only available in the client mode.
Requirement
● The WLAN interface is enabled.
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call up the command with the following parameters:
wlan signal-recorder <wlan 0/X> <ms (100 - 60000)> <sample_number (1 - 20000)>
display
The parameter has the following meaning:
Parameter
wlan 0/X
ms
sample_number
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 23)".
90
command.
or
cli#
Description
WLAN interface
The interval in milliseconds (ms) be-
tween acquisition of two measured
values
This parameter specifies how many
measured values will be recorded.
wlan signal-recorder <wlan 0/X> stop
Values or range of values
Enter a valid interface.
100 - 60000
1 - 20000
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
command.
show wlan signal-