hit counter script

Snmp Notify - Siemens SCALANCE W760 Configuration Manual

Industrial wireless lan
Hide thumbs Also See for SCALANCE W760:
Table of Contents

Advertisement

Network protocols
7.4 SNMP
7.4.2.12

snmp notify

Description
With this command, you configure the details of the SNMP notifications.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp notify <NotifyName> tag <TagName> type {Trap|Inform}
[{volatile|nonvolatile}]]
The parameters have the following meaning:
Parameter
NotifyName
tag
TagName
Type
Storage type
Result
The details of the SNMP notifications are configured.
318
Description
Name of the SNMP notification
Keyword for a target key
Name of the target key
Type of the SNMP notification
specifies whether the settings remain
following a restart:
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Range of values / note
max. 32 characters
-
max. 32 characters
Trap
generates a trap
Inform
generates a log entry or sends
an entry to the log server
volatile
The settings are lost after a
restart
nonvolatile
The settings are retained after
a restart
Configuration Manual, 11/2014, C79000-G8976-C351-03
(volatile):
(non-volatile):

Advertisement