hit counter script

No Wlan Ampdu; Wlan Ampdu Bytes-Limit - Siemens SCALANCE W760 Configuration Manual

Industrial wireless lan
Hide thumbs Also See for SCALANCE W760:
Table of Contents

Advertisement

Network structures
6.1 WLAN
6.1.5.6

no wlan ampdu

Description
With this command, you disable the sending of AMPDU data packets. If the function is
disabled, only AMPDU data packets can be received.
Requirement
● The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
no wlan ampdu
Result
The sending of AMPDU data packets is disabled.
Further notes
You display the setting with the
You enable the function with the
See also
wlan ampdu (Page 145)
6.1.5.7

wlan ampdu bytes-limit

Description
With this command, you specify the maximum size of the AMPDU data packet in bytes.
Note
This command is available only in access point mode.
146
show wlan advanced-11n <wlan 0/X>
command (default setting).
wlan ampdu
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
command.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720

Table of Contents