4.1.2.2

no web-session-timeout

Description
With this command, you disable the automatic logoff.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no web-session-timeout
Result
Automatic logoff is disabled.
Further notes
You enable automatic logoff with the
You display the current timeout setting with the
4.2

Signal recorder

This section describes the commands relevant for working with the signal recorder.
4.2.1

show wlan signal-recorder (Client)

Description
This command shows the status of the signal recorder. You can call the command before,
after or during the recording.
Note
This command is only available in the client mode.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
Functions specific to SCALANCE
command.
web-session-timeout
show web-session-timeout
4.2 Signal recorder