System time
5.3 SNTP client
5.3.5

Commands in the SNTP configuration mode

This section describes commands that you can call up in the SNTP configuration mode.
In the Global configuration mode, enter the
● If you exit the SNTP configuration mode with the
configuration mode.
● If you exit the SNTP configuration mode with the
Privileged EXEC mode.
5.3.5.1

sntp time diff

Description
With this command, you configure the time difference of the system time relative to the UTC
time.
Requirement
● The SNTP server must have started up.
● You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
+
-
hh
mm
Enter the time difference as follows:
● with sign
● without spaces
● Hours and minutes both two digits (with leading zero)
Default: no time difference
Result
The time zone of the system time is configured.
112
command to change to this mode.
sntp
Description
Time zones to the west of the SNTP server time zone
Time zones to the east of the SNTP server time zone
Number of hours difference
Number of minutes difference