5.2.3.1

ntp server

Description
With this command, you configure the connection to a server on the NTP client.
Requirement
You are in the NTP configuration mode.
The command prompt is as follows:
cli(config-ntp)#
Syntax
Call up the command with the following parameters:
ntp server{ipv4 <ip_addr> | fqdn-name <FQDN(100)>}[port<123,1025-
36564>][poll<seconds(64-1024)>]
The parameter has the following meaning:
Parameter
ipv4
ip_addr
fqdn-name
FQDN(100)
port
poll
seconds
For information on identifiers of addresses and interfaces, refer to the section "Addresses
and interface identifiers (Page 23)".
Result
The connection to a server is configured on the NTP client.
Further notes
You delete the connection to a server with the
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
Description
Keyword for an IPv4 address
Value for the IPv4 address of the time
server
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
UDP port of the time server
Keyword for the time after which the
time of day is requested again
Value for the time in seconds
no ntp server
System time
5.2 NTP client
Range of values / note
-
Enter a valid IPv4 address
-
Maximum of 100 characters
123
1025 ... 36564
Default: 123
-
64 ... 1024